SGC Metering - Gateway Business Park
Beancross Road, Grangemouth. UK. FK3 8WX
Tel: +44 1324 486 800 Email: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

Monday, February 06, 2012

gas

Pulsar

pulsar prod imagePulsar is a true "Level-A" simulator for flowcomputer pulse integrity verification in accordance with ISO 6551 /IP 252 / API Chapter 5.

It provides a versatile and multifunctional emulation of single pulse flowmeters, dual pulse flowmeters and density transducers. It is a portable device with front of panel interface, and operates using mains or battery power.

The supporting software PulsarConfig provides a dynamic operator interface and allows custom configuration, which can be stored and recalled.

Technical Requirements

Operating System

Microsoft® Windows 2000®, Windows XP®, or Windows Vista® Business.

Software Requirements

Microsoft Excel® 2002 or higher.

pulsar prod image

Dual Mode

Pulsar can be used to simulate a dual pulse flowmeter. This simulates a variety of potential fault conditions, which can be used to verify the fault tolerance and correct operation of flowcomputers and similar systems.

Independent Mode

Emulates a single pulse flowmeter, densitometer, or similar type signal. This eliminates the need for two separate simulator boxes.

pulsar prod imagePulsarConfig is installed on a PC, which interfaces to Pulsar. It is Microsoft® Excel® based and:

  • Gives an operator interface for custom configuration of Pulsar settings
  • Records Pulsar configuration
  • Allows remote operation
  • Displays dynamic data from Pulsar on a PC or laptop
  • Connects through Serial or Ethernet.

pulsar prod imageFrequency range - 1 Hz to 3 kHz

Phase angle (degrees) - 45, 90, 135, and 180

Duty cycle (Mark space ratio) - 10% to 60%

Add / Subtract pulses - Single or multiple pulse repetition

Local Counter & Rate Indicator - 8 digit, LCD, Reflective with Red LED backlight

Outputs - Two single-ended voltage dual pulse signal outputs. Voltage selectable as, +3V, +6V, +9V, +12V, or +24V. Two front panel 50ohm BNC connectors

Mains power - 110V - 240Vac

Battery power - Inbuilt rechargeable battery pack providing over 8 hours of free standing continuous use

Battery charge indicator - 10 Bar, Tri-colour flashing LED segment

Communication - Serial (RS232) or Ethernet connection.

Dimensions - 400mm(w) x 300mm(d) x 120mm(h)

Weight - 7 kg

Environmental - 0 to 50 degC, 0-70% RH.

pulsar prod image

  • Dual pulse simulation
  • Single pulse simulation
  • Selectable pulse phase shift
  • Selectable frequency (0-4000 Hz)
  • Selectable pulse amplitude (3V, 6V, 9V, 12V, or 24V)
  • Selectable pulse duty cycle
  • Preset pulse count (upto 99,999,999)
  • Continuous mode (Manual start / stop)
  • A and / or B output fail
  • Selectable LED display (A Count, B Count, or Hz)
  • Add single, or multiple, pulse function (added pulse simulation)
  • Subtract single, or multiple, pulse function (missing pulse simulation)
  • BNC output connections
  • Battery life indicator